The harmonic residual index: a spectral purity metric for magnetic hyperthermia RF generators


Creative Commons License

Yöner S. I., ÖZCAN İ. A., Akın O.

Journal of Physics D: Applied Physics, cilt.59, sa.35, 2026 (SCI-Expanded, Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 59 Sayı: 35
  • Basım Tarihi: 2026
  • Doi Numarası: 10.1088/1361-6463/ae9d8a
  • Dergi Adı: Journal of Physics D: Applied Physics
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Applied Science & Technology Source, Chemical Abstracts Core, Compendex, INSPEC, Academic Search Ultimate (EBSCO), Engineering Source (EBSCO)
  • Anahtar Kelimeler: magnetic hyperthermia, electromagnetic safety, harmonic distortion, specific absorption rate, spectral purity, radiofrequency characterization
  • Açık Arşiv Koleksiyonu: AVESİS Açık Erişim Koleksiyonu
  • Boğaziçi Üniversitesi Adresli: Evet

Özet

RF generators are core components of magnetic hyperthermia (MH) systems, yet output quality is rarely characterized beyond nominal frequency and amplitude. Harmonic distortion can introduce parasitic components that complicate reproducibility and accurate field characterization; MH-specific spectral quality indices remain limited. This study proposes two indices for RF generator output quality assessment in MH: the harmonic residual index ( (Formula presented) ) and a simulation-derived harmonic specific absorption rate (SAR) contribution index ( (Formula presented) ). A sinusoidal RF generator (50–200 kHz, 115 W) was evaluated with three coil configurations at 10%–100% power. Spatial magnetic-field measurements were acquired using a passive search coil, and (Formula presented) was computed pointwise to generate harmonic distortion maps. (Formula presented) was computed from the same spectra for benchmarking. Spatial mean HRI ( (Formula presented) ) and THD ( (Formula presented) ) were modelled using weighted power-law fitting. Inductive heating experiments (120–166.5 mg ml−1 MNP) evaluated the reliability of experimental calorimetry, motivating a shift toward simulation-based dosimetry. Finite element method (FEM) simulations of a simplified neck model driven by measured harmonics estimated relative harmonic SAR contributions and (Formula presented). (Formula presented) ranged from 0.17 ± 0.04 to 16.41 ± 3.48 (RMSE = 0.301–1.523) and increased monotonically with power level across all coils, while (Formula presented) showed smaller variations and less spatially structured behaviour. Experimental heating trials yielded marginal temperature elevations (⩽2.5 °C) with quantization errors, demonstrating that standard calorimetry is metrologically insufficient for SAR derivation at clinical field intensities. Conversely (Formula presented) ranged from 2.23E + 4 to 2.70E + 6, indicating low harmonic contributions relative to the fundamental under the tested conditions. (Formula presented) enables spatially resolved quantification of RF generator spectral impurities in MH systems and provides greater spatial sensitivity than (Formula presented) under the tested conditions. Combined with FEM screening of harmonic SAR contributions, the framework supports reproducible, standardized characterization of RF generator output quality for MH instrumentation quality assurance.