Parameter Estimation for Step‐Drawdown Tests


AVCI B. C.

Groundwater, cilt.30, sa.3, ss.338-342, 1992 (Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 30 Sayı: 3
  • Basım Tarihi: 1992
  • Doi Numarası: 10.1111/j.1745-6584.1992.tb02001.x
  • Dergi Adı: Groundwater
  • Derginin Tarandığı İndeksler: Scopus
  • Sayfa Sayıları: ss.338-342
  • Boğaziçi Üniversitesi Adresli: Evet

Özet

Step‐drawdown tests may be used to evaluate the well loss component of the well drawdown and to obtain estimates of the aquifer properties. A procedure that analyzes step‐drawdown tests with pumping stages of unequal time durations was formulated and developed into a computer program; the method is applicable to confined aquifers where the water‐level drawdowns are governed by the Theis well function. A least‐squares‐fit error analysis is used in the determination of the aquifer properties and the well loss component of the drawdown. Copyright © 1992, Wiley Blackwell. All rights reserved