Spatial but not temporal variation of ventricular repolarisation correlates closely with left ventricular function and size in patients with idiopathic dilated cardiomyopathy
Heart, cilt.83, sa.SUPPL. 1, 2000 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 83 Sayı: SUPPL. 1
- Basım Tarihi: 2000
- Dergi Adı: Heart
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
- Boğaziçi Üniversitesi Adresli: Hayır
Özet
Background: Heterogeneity of ventricular repolarisation is important in arrhythmogenesis. However, no information is available on the mechano-electrophysiological coupling of left ventricular (LV) function and myocardial repolarisation. Method: Ten 12-lead ECGs were recorded on each of the 69 patients (41M, age: 47.9±14.5) with idiopathic dilated cardiomyopathy (DCM). A novel T wave morphology (TWM) descriptors of spatial and temporal T wave variation and wavefront direction were automatically calculated from each ECG using an in-house custom-written programme. The mean values of 10 ECGs were taken. Echocardiography, metabolic exercise (VO2max), microvolt T-wave alternans (TWA), late potential (LP) and ventricular premature beats (VPB) were also measured. Student's t-test and linear regression analysis were used. Results: Spatial T wave morphology dispersion (TMO), including dispersion of the ascending (TMDpre) and descending (TMDpost) parts of the T wave, and the vector deviation between the depolarisation and repolarisation (TCRT) significantly correlated with LV function and size (see table). However, the temporal variation of the interlead relationship during T wave (LD1 & LD2) did not correlate with LV function and size. VO2max, TWA, LP and VPB did not correlate any of the above spatial or temporal ventricular repolarisation parameters. Conclusions: In DCM patients: 1) We demonstrated for the first time that LV function and size are dependent strongly on spatial but not temporal variation of ventricular repolarisation; 2) Ventricular repolarisation is not related to the metabolic function, TWA, LP or VPB; 3) Spatial and dynamic variation of ventricular repolarisation can be measured on 12-lead ECG using this novel computerised TWM analysis and is useful in helping to understand repolarisation process. LV ejection fraction LV diast. diameter LV syst. diameter TMDpre R=0.40, p=0.005 R=0.29, p=0.046 R=0.37, p=0.011 TMD R=0.46, p=0.001 R=0.36, p=0.013 R=0.42, p=0.003 TMDpost R=0.43, p=0.003 R=0.34, p=0.020 R=0.38, p=0.007 TCRT R=0.56, p<0.0001 R=0.53, p<0.0001 R=0.57, p<0.0001.