A randomized crossover trial to compare automated insulin delivery (The artificial pancreas) with carbohydrate counting or simplified qualitative meal-size estimation in type 1 diabetes


Haidar A., Legault L., Raffray M., Gouchie-Provencher N., Jafar A., Devaux M., ...Daha Fazla

Diabetes Care, cilt.46, sa.7, ss.1372-1378, 2023 (SCI-Expanded, Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 46 Sayı: 7
  • Basım Tarihi: 2023
  • Doi Numarası: 10.2337/dc22-2297
  • Dergi Adı: Diabetes Care
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, PASCAL, Agricultural & Environmental Science Database, CAB Abstracts, CINAHL, EMBASE, International Pharmaceutical Abstracts, Public Affairs Index, Veterinary Science Database, DIALNET, Nature Index
  • Sayfa Sayıları: ss.1372-1378
  • Boğaziçi Üniversitesi Adresli: Hayır

Özet

OBJECTIVE: Qualitative meal-size estimation has been proposed instead of quantitative carbohydrate (CHO) counting with automated insulin delivery. We aimed to assess the noninferiority of qualitative meal-size estimation strategy. RESEARCH DESIGN AND METHODS: We conducted a two-center, randomized, crossover, noninferiority trial to compare 3 weeks of automated insulin delivery with 1) CHO counting and 2) qualitative meal-size estimation in adults with type 1 diabetes. Qualitative meal-size estimation categories were low, medium, high, or very high CHO and were defined as <30 g, 30-60 g, 60-90 g, and >90 g CHO, respectively. Prandial insulin boluses were calculated as the individualized insulin to CHO ratios multiplied by 15, 35, 65, and 95, respectively. Closed-loop algorithms were otherwise identical in the two arms. The primary outcome was time in range 3.9-10.0 mmol/L, with a predefined noninferiority margin of 4%. RESULTS : A total of 30 participants completed the study (n = 20 women; age 44 (SD 17) years; A1C 7.4% [0.7%]). The mean time in the 3.9-10.0 mmol/L range was 74.1% (10.0%) with CHO counting and 70.5% (11.2%) with qualitative meal-size estimation; mean difference was 23.6% (8.3%; noninferiority P = 0.78). Frequencies of times at <3.9 mmol/L and <3.0 mmol/L were low (<1.6% and <0.2%) in both arms. Automated basal insulin delivery was higher in the qualitative meal-size estimation arm (34.6 vs. 32.6 units/day; P = 0.003). CONCLUSIONS : Though the qualitative meal-size estimation method achieved a high time in range and low time in hypoglycemia, noninferiority was not confirmed.